Sensitive detection and identification of isovanillin aerosol particles at the pg/cm^3 mass concentration level using Raman spectroscopy
June 8, 2015
Journal Article
Author:
Published in:
Aerosol Sci. Technol., Vol. 49, No. 9, 2015, pp. 753-6.
R&D Area:
Summary
A compact Raman spectroscopy system with high sensitivity to chemical aerosols has been developed. This system has been used to detect isovanillin aerosols with mass concentration of 12 pg/cm3 in a 15 s signal integration period with a signal-to-noise ratio of 32. We believe this represents the lowest chemical aerosol concentration and signal integration period product ever reported for a Raman spectroscopy system. The Raman system includes (i) a 10 W, 532-nm cw laser, (ii) an aerosol flow cell, (iii) a 60x aerosol concentrator, (iv) an f/1.8 Raman spectrometer with a spectral range of 400-1400 cm^-1 and a resolution of 4 cm^-1, and (v) a low-noise CCD camera (1340 x 400 pixels). The collection efficiency of the Raman system has been determined to be 2.8%. Except for the laser cooling subsystem, the Raman system fits in a 0.61 m x 0.61 m x 0.61 m box.