Detection statistics in Geiger-mode avalanche photodiode quad-cell arrays with crosstalk and dead time

Published in:
IEEE Sens. J., Vol. 15, No. 4, April 2015, pp. 2133-43.

Summary

The detection statistics of Geiger-mode photodetector subarrays with a combination of reset-time blocking loss and optical crosstalk are investigated. Closed-form expressions are obtained for the means and covariances of the numbers of counts in 2 x 2 subarrays (quad cells) used in Shack-Hartmann wavefront sensors. The predicted wavefront sensing precision is compared with that obtained with a charge-coupled device-based wavefront sensor with readout noise. The results of the theory are also used to predict photon transfer curves for the Geiger-mode device and these are compared with experiment.
READ LESS

Summary

The detection statistics of Geiger-mode photodetector subarrays with a combination of reset-time blocking loss and optical crosstalk are investigated. Closed-form expressions are obtained for the means and covariances of the numbers of counts in 2 x 2 subarrays (quad cells) used in Shack-Hartmann wavefront sensors. The predicted wavefront sensing precision...

READ MORE

Development of CCDs for REXIS on OSIRIS-REx

Summary

The Regolith x-ray Imaging Spectrometer (REXIS) is a coded-aperture soft x-ray imaging instrument on the OSIRIS-REx spacecraft to be launched in 2016. The spacecraft will fly to and orbit the near-Earth asteroid Bennu, while REXIS maps the elemental distribution on the asteroid using x-ray fluorescence. The detector consists of a 2x2 array of back-illuminated 1kX1k frame transfer CCDs with a flight heritage to Suzaku and Chandra. The back surface has a thing p+-doped layer deposited by molecular-beam epitaxy (MBE) for maximum quantum efficiency and energy resolution at low x-ray energies. The CCDs also feature an integrated optical-blocking filter (OBF) to suppress visible and near-infrared light. The OBF is an aluminum film deposited directly on the CCD back surface and is mechanically more robust and less absorptive of x-rays than the conventional free-standing aluminum-coated polymer films. The CCDs have charge transfer inefficiencies of less than 10^-6, and dark current of le-/pixel/second at the REXIS operating temperature of -60 degrees C. The resulting spectral resolution is 115 eV at 2 KeV. The extinction ratio of the filter is ~10^12 at 625 nm.
READ LESS

Summary

The Regolith x-ray Imaging Spectrometer (REXIS) is a coded-aperture soft x-ray imaging instrument on the OSIRIS-REx spacecraft to be launched in 2016. The spacecraft will fly to and orbit the near-Earth asteroid Bennu, while REXIS maps the elemental distribution on the asteroid using x-ray fluorescence. The detector consists of a...