Publications

Refine Results

(Filters Applied) Clear All

Improving RUC-1 wind estimates by incorporating near-real-time aircraft reports

Published in:
Weather For., Vol. 15, No. 4, August 2000, pp. 447-460.

Summary

A verification study of wind accuracy is presented for wind nowcasts generated by augmenting Rapid Update Cycle (RUC) wind forecasts with near-real-time aircraft reports using the Integrated Terminal Weather System (ITWS) gridded winds algorithm. Aircraft wind reports collected between the end of the RUC data collection interval and the time each RUC forecasts is valid are available for use in augmenting the RUC wind forecast to form a wind nowcast. The 60-km resolution, hourly RUC-1 wind forecasts are used. ITWS-based nowcast wind errors and RUC forecast wind errors are examined statistically over a 1-yr dataset. The addition of the recent aircraft reports significantly reduces the rms vector error and the 90th percentile vector error. Also reduced is the number of hours of sustained large errors and the correlation among errors. The errors increase with increasing wind speed, in part due to an underestimation of wind speed that increases with increasing wind speed. The errors in the augmented wind fields decrease with increasing numbers of Aircraft Communications Addressing and Reporting System reports. Different types of weather are also seen to influence wind field accuracy.
READ LESS

Summary

A verification study of wind accuracy is presented for wind nowcasts generated by augmenting Rapid Update Cycle (RUC) wind forecasts with near-real-time aircraft reports using the Integrated Terminal Weather System (ITWS) gridded winds algorithm. Aircraft wind reports collected between the end of the RUC data collection interval and the time...

READ MORE

Weather radar development and application programs

Author:
Published in:
Lincoln Laboratory Journal, Vol. 12, No. 2, 2000, pp. 367-382.

Summary

Weather phenomena such as microburst wind shear and severe thunderstorms are major concerns to the aviation industry. A number of significant airplane accidents have resulted from wind-shear encounters during takeoff and landing, and thunderstorms are a major contributor to airplane delay. Providing fully automated and timely warnings of these phenomena by radar is challenging because it requires rapid and accurate analysis of the three-dimensional storm structure in the presence of intense ground-clutter returns. For the last two decades, Lincoln Laboratory has been tackling this challenge by applying advanced radar signal- and image-processing techniques to weather radar data. The resulting technology is being deployed in radar-based weather information systems at major airports throughout the United States. We first discuss the salient meteorological factors that contribute to the formation of microburst wind shear, then we provide some general background on the use of pulse-Doppler radar for weather detection. We describe two specific Lincoln Laboratory programs that have generated deployed systems: the Terminal Doppler Weather Radar (TDWR) and the ASR-9 Weather Systems Processor (WSP). The article concludes with a discussion of future detection strategies that emphasizes the fusion of weather radar data by the Integrated Terminal Weather System (ITWS).
READ LESS

Summary

Weather phenomena such as microburst wind shear and severe thunderstorms are major concerns to the aviation industry. A number of significant airplane accidents have resulted from wind-shear encounters during takeoff and landing, and thunderstorms are a major contributor to airplane delay. Providing fully automated and timely warnings of these phenomena...

READ MORE

The design and validation of the ITWS synthetic sensor data generator

Published in:
MIT Lincoln Laboratory Report ATC-289

Summary

The Integrated Terminal Weather System (ITWS) is an aviation safety and air traffic management decision support system that acquires data from various FAA and NWS sensors and generates a number of products for dissemination to FAA facilities managing air traffic in the terminal area. The development and demonstrations of ITWS have been conducted over a multi-year period at several major airports (Memphis, TN, Orlando, FL, Dallas, TX, and New York, NY). Although there are many meteorological events observed at these four airports, the experimental test data sets obtained will not fully suffice for ITWS qualification testing because of limitations in the severity of the weather events and because of the sensor configurations available at these locations. This report describes the design and validation of the Synthetic Data Generator (SDG), which is a tool to provide a production ITWS system with meteorologically consistent scenarios and full ITWS sensor configurations that will create maximal computational loads that can be expected when the system is deployed. Also, the SDG will be a tool for ongoing ITWS maintenance and support. As such, the SDG will complement the extensive experimental data sets collected at the four ITWS demonstration sites. The SDG is designed to specify parameters for a collection of meteorological models describing the various weather phenomena, their motion, appearance, and growth/decay. The software creates several three-dimensional (3D) grids of reflectivity and velocity at each time-step. Finally, the SDG generates sensor (i.e., TDWR, NEXRAD, ASR-9) data by applying the model for each specific sensor's measurements to the 3D grids. The validation of the meteorological model and the sensor model data have been accomplished using a display tool and by assessing results numerically.
READ LESS

Summary

The Integrated Terminal Weather System (ITWS) is an aviation safety and air traffic management decision support system that acquires data from various FAA and NWS sensors and generates a number of products for dissemination to FAA facilities managing air traffic in the terminal area. The development and demonstrations of ITWS...

READ MORE

Weather sensing and data fusion to improve safety and reduce delays at major west coast airports

Summary

The objective of this study was to analyze the weather sensing and data fusion required to improve safety and reduce delays at a number of west coast airports that are not currently scheduled to receive an Integrated Terminal Weather System (ITWS). This report considers the Los Angeles (LAX), San Francisco (SFO), Seattle (SEA) and Portland, OR (PDX) international airports. A number of visits were made to the various ATC facilities to better understand their weather decision support operational needs. Analyses were made of an incident of lightning strikes to two aircraft at SEA in February 1999, and a prototype terminal winds product was developed for LAX that uses profilers as well as plane reports to update the the National Weather Service (NWS) Rapid Update Cycle (RUC) winds estimates. We found that an augmented ITWS could potentially address safety concerns for triggered lightning strikes and vertical wind shear in winter storms at Portland and Seattle. An augmented ITWS terminal winds product (that uses wind profiler data in addition to the current ITWS sensors) could provide very large delay reductions for LAX and SFO during winter storms as a component of a wake vortex advisory system. This augmented product also could provide significant delay reduction benefits at SEA. The sensors required to obtain the projected benefits at SFO do not exist currently. Portland may warrant additional sensors to address the vertical wind shear problems, and LAX would require additional sensors for a wake vortex advisory system. We recommend near-term experimental measurements at PDX to determine the optimum sensor mix and that an operational evaluation of the prototype augmented ITWS terminal winds product be carried out at LAX to determine if the current sensor mix can meet operational needs. Lightning strike data at SEA and PDX should be analyzed to determine if a proposed triggered lightning predictant is accurate.
READ LESS

Summary

The objective of this study was to analyze the weather sensing and data fusion required to improve safety and reduce delays at a number of west coast airports that are not currently scheduled to receive an Integrated Terminal Weather System (ITWS). This report considers the Los Angeles (LAX), San Francisco...

READ MORE

An evaluation of the ASR-9 weather channel based on observations from the ITWS prototypes

Published in:
MIT Lincoln Laboratory Report ATC-270

Summary

The Federal Aviation Administration's (FAA) Airport Surveillance Radar (ASR-9) is a high-scan-rate system which provides a "critical" function in terms of air traffic control (ATC). In addition to its primary role of air traffic surveillance, the system also generates precipitation data for display on air traffic specialists' radar scopes and for use by automated systems such as the Integrated Terminal Weather System (ITWS) and Weather Systems Processor (WSP). Air traffic managers use these data to provide optimum routes for aircraft operating in and near the Terminal Radar Approach Control (TRACON) airspace. The primary advantage of the ASR-9 - as an aviation weather radar - over either the Terminal Doppler Weather Radar (TDWR) or the Next Generation Weather Radar (NEXRAD) is the rapid update rate, i.e., 30 seconds, which provides air traffic managers with a more accurate representation of weather echo location within the sensor's domain. This is far superior toeither the TDWR or NEXRAD, which takes from 2.5 to 6 minutes to create a volume scan, depending on the scan strategy. The sensor is also quite reliable, with limited down time. An analysis of ASR-9 data from the ITWS prototypes has uncovered a number of problems, which impact the quality of the precipitation data. The data quality issues discussed are overly aggressive ground clutter suppression, polarization mode issues, hardware failures associated with high beandlow beam switching, attenuatiodsignal depolarization, beam-filling losses, bright- band contamination, distant weather contamination, calibration issues, and radadantenna failures. The recommendations to address the ASR-9 data quality issues can be grouped into three categories: "Variable Site Parameter (VSP)" adjustments, hardware component maintenance checks, and automated flagging of data quality problems. The report includes discussion of the frequency and characteristics of each degradation, presenting both hardware and non- hardware related problems, and concludes with proposed solutions to the problems and recommendations designed to improve the overall utility of the ASR-9 precipitation data.
READ LESS

Summary

The Federal Aviation Administration's (FAA) Airport Surveillance Radar (ASR-9) is a high-scan-rate system which provides a "critical" function in terms of air traffic control (ATC). In addition to its primary role of air traffic surveillance, the system also generates precipitation data for display on air traffic specialists' radar scopes and...

READ MORE

Wind shear detection using the Next Generation Airport Surveillance Radar

Author:
Published in:
MIT Lincoln Laboratory Report ATC-266

Summary

The Federal Aviation Administration (FAA) is deploying a Weather Systems Processor (WSP) for the current-generation Airport Surveillance Radar - ASR-9. This modification exploits the coherency of the ASR-9 to perform Doppler wind measurement. Signature recognition algorithms then automatically detect low altitude wind shear phenomena, track thunderstorm motion and display appropriate graphical and alphanumeric alerts to air traffic control (ATC) personnel. The FAA and U.S. Air Force are now procuring an ASR-11 to replace older terminal surveillance radars at facilities that did not receive the ASR-9. Although the antenna pattern, scan rate and energy-on-target of the ASR-11 match the corresponding parameters of the ASR-9, two other characteristics are markedly different. It utilizes a low peak power solid state transmitter that requires transmission of long, coded waveforms and a pulse compression receiver. Secondly, its pulse transmission sequence consists of short (five-pulse) bursts at both different pulse-repetition frequencies (PRF) and different RF frequencies. In this report, we assess the technical and operational issues associated with adding a WSP to the ASR-11. The existing WSP data processing and display technology are largely re-usable for the ASR-11 based WSP. Ground clutter filter coefficients and the length and number of coherent processing intervals would need to be changed to conform to the ASR-11 pulse transmission strategy, and straightforward adaptations to the equations used in the pulse-pair weather reflectivity and Doppler velocity estimation would be required. With these changes, the ASR-11 could host the WSP, subject to performance degradations for low reflectivity wind shear phenomena such as dry microbursts and gust fronts. A benefits assessment waas performed to evaluate the operational requirements for an ASR-11 based WSP. Given that the FAA has already committed to deploy improved Low Level Wind Shear Alert Systems (LLWAS) at most ASR-11 airports, the incremental safety benefits for the ASR-11 WSP appear to be less than the cost of the equipment. A case can be made for deployment based on "situational awareness" benefits that the WSP has been demonstrated to provide to air traffic controllers. We estimate that the value to the public and airline industry of reductions in aircraft delay, and avoidance of unnecessary diversions, would be in excess of eight million dollars per year tallied across 18 of the larger ASR-11 equipped airports.
READ LESS

Summary

The Federal Aviation Administration (FAA) is deploying a Weather Systems Processor (WSP) for the current-generation Airport Surveillance Radar - ASR-9. This modification exploits the coherency of the ASR-9 to perform Doppler wind measurement. Signature recognition algorithms then automatically detect low altitude wind shear phenomena, track thunderstorm motion and display appropriate...

READ MORE

The FAA Terminal Convective Weather Forecast product: scale separation filter optimization

Published in:
29th Int. Conf. on Radar Meteorology, 12-16 July 1999.

Summary

A large percentage of serious air traffic delay at major airports in the warm season is caused by convective weather. The FAA Convective Weather Product Development team (PDT) has developed a Terminal Convective Weather Forecast product (TCWF) that can account for short-term (out to 60 min) systematic growth and decay of thunderstorms. The team began work three years ago by evaluating air traffic user needs and requirements. We found that users were willing to trade off forecast accuracy for longer lead times, especially for air traffic management plans that were easy to implement or that incurred low risk (Forman, et al., 1999). The PDT was able to develop an operationally useful forecast product that has been demonstrated in Dallas, TX since March, 1998 (Hallowell, et al., 1999). Further improvements have been made, and testing is now taking place at both Dallas and Orlando, FL. This paper summarizes the basic algorithm methodology and presents quantitative results on optimization of the scale separation filter, which is an integral aspect of the forecast algorithm.
READ LESS

Summary

A large percentage of serious air traffic delay at major airports in the warm season is caused by convective weather. The FAA Convective Weather Product Development team (PDT) has developed a Terminal Convective Weather Forecast product (TCWF) that can account for short-term (out to 60 min) systematic growth and decay...

READ MORE

Review of NYC ITWS during the September 7, 1998 severe weather event

Published in:
Project Report ATC-269, MIT Lincoln Laboratory

Summary

The New York City Integrated Terminal Weather System (ITWS) prototype became operational for the first time on August 30, 1998. Although this was near the end of the region's convective season, site staff were afforded a unique chance to assess the system's performance during Labor Day weekend on the afternoon of September 7 when a line of severe thunderstorms wreaked havoc over large areas of the Tri-state region. The storm with gusts reported as high as 80 mph, caused fatalities as boats overturned and trees fell on cars. Tornadoes were confirmed over New Jersey and Long Island, with major structural damage occurring in other areas as the result of strong straight-line winds and hail reported as large as 1.75 inches in diameter. Significant airport delays were experienced at the three major New York airports (over 600 flights delayed at least 15 minutes) and several hundred flights were cancelled. This report will assess the performance of ITWS and NEXRAD products during the time severe weather impacted the TRACON area, from about 1700 to 1930 UTC on September 7 (hereafter all times will be given in UTC). It will also discuss the synoptic weather setting and conclude with a section on the operational benefits users derived from ITWS on this day.
READ LESS

Summary

The New York City Integrated Terminal Weather System (ITWS) prototype became operational for the first time on August 30, 1998. Although this was near the end of the region's convective season, site staff were afforded a unique chance to assess the system's performance during Labor Day weekend on the afternoon...

READ MORE

A refinement of thunderstorm climatology for the terminal radar control airspace

Published in:
8th Conf. on Aviation, Range and Aerospace Meteorology, ARAM, 10-15 January 1999.

Summary

Convective storms pose a significant threat to aviation safety, and often result in substantial fl ight delays for the commercial aviation industry. The overall impact of these storms is typically based on thunderstorm climatologies and are often one of the factors used in decisions by the US government regarding the operational benefits and allocation of its weather surveillance resources. These climatologies are based on the average number of days that a thunderstorm is observed at a particular airport. Due to the nature of the criteria used to identify a thunderstorm, the climatological statistics often do not accurately represent the number of thunderstorms that impact an airport's operations. The present study utilizes data from the Dallas Ft. Worth International Airport (DFW) and the Orlando International Airport (MCO) to identify deficiencies in the climatological data as it applies to aviation applications. A spatially representative climatology is presented as a more accurate climatology for use in evaluating the impact of convection on an airport's operations. This type of climatological estimate of thunderstorm frequency significantly increases the estimated number of thunderstorms impacting an airport and their associated costs.
READ LESS

Summary

Convective storms pose a significant threat to aviation safety, and often result in substantial fl ight delays for the commercial aviation industry. The overall impact of these storms is typically based on thunderstorm climatologies and are often one of the factors used in decisions by the US government regarding the...

READ MORE

Addressing the weather delay problems of the New York City airports with the Integrated Terminal Weather System

Author:
Published in:
8th Conf. on Aviation, Range, and Aerospace Meteorology, 10-15 1999.

Summary

The three major New York City (NYC) air carrier airports (Kennedy, LaGuardia, Newark) currently experience high delays due to adverse terminal weather, both in an absolute sense and relative to other major airport complexes. Significantly expanding the NYC airports (e.g., by adding new runways) to reduce delays is not feasible. One alternative is to provide aviation weather decision support systems to air traffic, airline, and airport operations personnel to help them operate more safely and effectively with the existing runway/taxiway complexes. Under an innovative partnership between the Port Authority of New York and New Jersey and the Federal Aviation Administration (FAA), Massachusetts Institute of Technology, Lincoln Laboratory has installed and is currently operating a functional prototype Integrated Terminal Weather System (ITWS) to conduct research on improving the safety and efficiency of operations at the NYC airports during adverse weather. The New York terminal area provides a stringent test of the ITWS ability to safely reduce delays due to both the meteorology and the operational usage challenges not found at the earlier ITWS test locations of Orlando, Memphis, and Dallas. In this paper, we describe key features of the New York terminal environment and the ITWS prototype, the initial experience in addressing the meteorological and operational usage challenges of the New York terminal area, and describe plans for the coming years.
READ LESS

Summary

The three major New York City (NYC) air carrier airports (Kennedy, LaGuardia, Newark) currently experience high delays due to adverse terminal weather, both in an absolute sense and relative to other major airport complexes. Significantly expanding the NYC airports (e.g., by adding new runways) to reduce delays is not feasible...

READ MORE